The IMIT TECHNO WPT Thermostat allows numerous adjustments to the room temperature, both weekly and daily. It is suitable for cast iron radiators, aluminum radiators, and underfloor heating. It provides a 30-minute interval connection and has a wide and easily readable display.

This thermostat can operate in either heating or cooling mode. Once the mode is selected, the thermostat's logic changes as follows:

If in HEATING mode: The thermostat closes the contact if the detected temperature is lower than the set temperature.
Conversely, in COOLING mode: The thermostat's logic aims to close the contact if the detected temperature is higher than the set one.

The thermostat is therefore applicable where the system is designed to cool environments, such as offices with fan-coil units that are irrigated by the cooling system.

If you don't want to use the program, you can always use the manual mode to operate the heating around the clock.

Adjustments and Display

The Display

The display of the IMIT TECHNO WPT Thermostat allows for a clear view of the parameters:
At the top, we see the currently set day.
On the next line, we see:

  • Following that, there is:
    • The currently set time
    • The currently set temperature
  • The currently detected temperature
  • The operational icons
  • The chart of set temperatures and times
    • Horizontally, there are the hours from midnight to midnight of the current day.
    • Vertically, there are the operating temperatures for the reference times.

Button Functions

The IMIT TECHNO WPT allows adjustments through the following buttons:

  • Menu Button: Allows access to the configuration menu
  • Prog Button: Allows for the programming of the heating
  • Arrow Buttons: Allow movement through the various thermostat menus; in the center, there is the confirmation button
  • Mode Button: Allows the selection of the operation type among: AUTomatic, MANual, OFF
  • Esc Button: To exit the menu and configuration.

Set the Correct Time

Setting the current time and day is essential to properly use the thermostat IMIT Techno WPT in automatic mode.

  • Set the display to 24H or 12H using the up arrow and then press OK.
  • Set the hour by pressing the Up Arrow button multiple times until the correct time is displayed, then press OK.
  • Set the minutes by pressing the Up Arrow button multiple times until the correct time is displayed, then press OK.
  • Set the correct day using the Left and Right arrows, then press OK.

Access to the Settings Menu

Press Menu to enter the settings menu, then press the Left or Right arrow to scroll through the definable settings.

  • Press the Up Arrow to set the season mode to Summer/Winter.
  • Press OK to set the clock as before.
  • Press the Up Arrow to set the temperature unit (Fahrenheit or Celsius).
  • Press the Up Arrow to set the language.
  • Press the Up Arrow to adjust the brightness.
  • Press ESC to exit the menu, and all settings are saved.

Checking the Operation

If the set temperature for the current operating period is higher than the detected room temperature, the thermostat is said to be "calling". An icon of a small flame appears, indicating that the thermostat is signaling the boiler to turn on.

Setting an Operating Program

Instructions for adjusting the correct time on the thermostat display.

Common Issues

The thermostat isn't turning on the heating!

Always make sure that:

  • Boiler Side:
    • The boiler is not in error.
    • The boiler is correctly pressurized (1.5 bar).
    • The boiler is in Winter mode.
  • Thermostat Side:
    • Ensure the IMIT TECHNO WPT thermostat has charged batteries.
    • The batteries are disposable and of excellent quality.
    • Do not use rechargeable batteries.
    • The thermostat is correctly "calling" (the flame symbol appears).

Frequently Asked Questions

Your questions and the most frequently posed ones:

How can I set a specific temperature on my thermostat?

Changing the temperature for manual programming is very simple:

  • Press the Up Arrow to increase the desired temperature.
  • Press the Down Arrow to decrease the temperature.

For automatic operation:

  • You have 3 available temperatures (T1, T2, T3).
  • Press Prog to enter programming mode.
  • Press Mode to enter temperature programming.
  • You can now modify the value of T1.
  • Press Mode to move to the modification of T2 value.
  • Press Mode to move to the modification of T3 value.
  • After adjusting the temperatures, press Mode to return to time programming.
  • Press Esc to return to the initial operating screen.

What does the flame symbol on the thermostat display indicate?

The flame symbol displayed on the IMIT TECHNO WPT thermostat indicates whether the thermostat is correctly "calling".

In fact, the thermostat is usually connected to the heating device through a contact; the thermostat closes this contact to initiate heating.

The flame indicator shows us if the thermostat is currently requesting heat production.

What is the ideal place to install the IMIT TECHNO WPT thermostat in my home?

The ideal location for installing this device includes:

  • A corridor
  • A bedroom

Do not install the thermostat near heat sources or places affected by cold air drafts. Therefore, avoid:

  • Proximity to radiators
  • Proximity to wood-burning fireplaces
  • Installation in kitchens or bathrooms
  • Proximity to doors or windows
  • Installation on perimeter walls facing the outside of the building

What are the recommended temperatures for the different modes (Comfort, Economic, Frost Protection) on the IMIT TECHNO WPT thermostat?

We suggest the following operating temperatures:

  • For Comfort temperature, we suggest setting a temperature of 18 degrees, increasing to your preferred room temperature.
  • The suggested Economic temperature is between 16 and 18 degrees.
  • The recommended Frost Protection temperature is 10 degrees.

Useful Tips

Tips for optimal use of the IMIT TECHNO WPT thermostat.

The thermostat has 3 Temperature settings (Comfort / Economic / Frost Protection).

  • We suggest a Comfort temperature of 18°C +/- to be used when the apartment is occupied and you want to achieve maximum comfort.
  • We recommend an Economic temperature of 16°C to be used when the apartment is unoccupied and during the night.
  • You can take advantage of the thermostat's ability to program in half-hour intervals by using this strategy:
  • If you have aluminum radiators, you can turn on the heating about 30 minutes earlier due to the high efficiency of this material.
  • If you have cast iron radiators, on the other hand, turn on the heating at least an hour earlier to allow the heating system to reach its operational state. However, you can turn it off an hour earlier to fully benefit from the thermal inertia of this type of radiator.

Battery Replacement

To replace the batteries in the IMIT TECHNO WPT thermostat, use the right and left sides to remove the base from the panel and access the battery compartment.

Replace the batteries approximately every 2 years to prevent malfunctions in the heating system.

Mounting and Installation

The regulator should be mounted in the reference room.

The unit should be placed where it is easiest to measure the average room temperature, away from sunlight or cold sources.
The unit should be situated away from sources of disturbance, for instance:

  • Do not mount on metallic surfaces.
  • Do not place near electrical cables, electrical devices such as PCs, TVs, microwave ovens, etc.
  • Do not install the unit close to metal walls or construction elements made of metal.

Technical Specifications